Partial discharge in purifier



  • Partial discharge occurs in Mitsubishi hidden series(GSH-1 specification model only)
  • When the purifier detects a loss in back pressure on the line connecting the water outlet to the purifier inlet control unit sends a signal for partial discharge

Partial discharge


  • In case of partial discharge (GSH-1 specification model) ,the operating water for partial discharge is regulated by the solenoid valve SV9 and introduced into the bowl closing water pressure chamber via feeding device. 
  • When the bowl closing water pressure chamber has been filled up; the bowl opening water overflows into the bowl opening water pressure chamber; depressing the main cylinder to open the bowl instantly, causing the purifier to partially discharge


1 comment:

  1. Thanks for shedding light on partial discharge in purifiers, especially in the Mitsubishi hidden series. Understanding these intricacies is crucial for maintaining optimal performance. Speaking of which, have you heard about the Fluke ii910 Precision Acoustic Imager? It's a powerful tool for detecting partial discharges in electrical equipment, offering precise insights for preventive maintenance. Might be worth exploring for enhanced purifier diagnostics!