Sounding and Ullage explained for and by a dummy

Sounding-Is the measured height (in meters) from the bottom of the tank to the liquid surface.
Ullage-Is the measured height (in metre) from the liquid surface to the top of the tank or sounding pipe.

A simplified diagram to better explain these two concepts.

Manual procedure to take a sounding using sounding tape 

  1. Open the cap of sounding pipe 
  2. Lower the sounding tape lower the bob until it touches the bottom (the striker plate)
  3. Heave up the sounding tape and note the height of the liquid on the tape

Other methods to take Sounding onboard

  1. A mechanical sounding gauges-Provision such as float gives the corresponding quantity of tank attached to a point through a pulley
  2. Bubber gauge-uses the principle fo hydrostatic pressure to give the liquid level
  3. Differential pressure guage-Uses the difference between two pressure points within a process system to give the level
  4. Electronic sounding gauge- Senses the pressure inside the sounding pipe or the tank and sends the signal  to a receiver. The signal is translated using a PLC circuit, and the value of the liquid level is determined
  5. Ultrasonic sounding gauge- Uses the principle of echo sounder by throwing an ultrasonic wave from the gauge and is being detected by a sensor, routes it through a microprocessor,r and provides a digital value for the sounding or level of liquid

Manual procedure to take an Ullage using Sounding Tape 

  1. Open the cap of the sounding pipe 
  2. Find out the depth of the sounding pipe and note the value
  3. Lower the sounding tape until the bob touches the liquid surface. This can be felt by feeling the resistance, note the height of the tape let go 
  4. Heave up the sounding tape and note the height of the liquid on the tape(measured value)   
Ullage= (Height of tape let go ーHeight of the liquid on tape)
Sounding= (Depth of sounding pipeーUllage)
Example1: If 1.64m is the depth of the sounding pipe and the height of the tape let go is 1m  and the height of the liquid measured on the tape is 0.14m
Then 
Using the above-mentioned methods and formula
  • Ullage=1.0ー0.14=0.86m
  • Sounding=1.64ー0.86=0.78m

UTI Gauges

UTI's are heavily used in tankers by the chief officers for accurate cargo calculation, used to primarily gives 3 parameters or data.
  • Oil level -ullages
  • Oil-water interface
  • Temperature
Different maker have different designs and models, to ensure they remain correct in measurement,UTI's are calibrated ones every year by specialist

Practical tip for accurate Sounding/Ullage

  • Use genuine and high-quality tapes.
  • Clean and maintain the sounding tape regularly.
  • Sounding tapes to be cleaned and stowed in a bucket after use.
  • Use appropriate paste ie, water finding paste or oil finding paste.
  • Consider the effect of trim and list of the ship.
  • For accuracy take sounding when vessel at relative calm conditions.

Calculating Slip

Slip is a very important calculation that goes into the noon report, official logbook, etc. Slip is the difference between engine speed and the actual speed of the vessel and it is calculated in percentage.

Slip are of two types 

  • positive-due to hull fouling, wind and/or current running against the ship 
  • negative slip wind and/or current running with the ship 
Step 1- Find engine distance
  • avg rpm=revolutional counter /(running hour*60)

revolution counter can be found out by finding the difference between the present counter and previous counter and then calculate average rpm from the above formula

  • Engine distance=(pitch *avg rpm*60*running hours)/(1000*1.8253)
or
  • Engine distance=(pitch *revolution counters )/(1000*1.8253)
where the pitch is in meters

Step 2 -Find actual distance
This is normally provided by the bridge team.

Step 3 Calculate slip

Slip%={(engine distance-actual distance)/engine distance}*100



How to calculate fuel oil consumption

Basic Fundamentals
  • Fuel is always measured in tonnes because mass  is constant(weight does not change with temperature)
  • Whereas  volume changes with temperature(volume of bunker increase with temperature (and vice-versa)
  • Fuel consumption is calculated over a specific period of time, generally over a 24 hour period
Basic Formula for Mass=Volume*Density
units are mass tonnes,
volume is m3,
density is tonne/m3

Step1-Volume- Reading of common fuel flow meter counters should be taken at a specific interval of time say 24hour.

Formula for volume=(Present counter- Previous counter)*0.001 

where Flowmeter counter measures the flow in lit/h
The correctional factor is used to convert litre/hr to m3/hr                                                                      1litre/hr=0.001 cubic metre/hr


Step 2-Density -BDN provides density  at 15deg cel
(Which poses a problem as fuel is flowing at a temperature higher than 15deg
Therefore, we need to consider temperature corrected density at tonne/m3)

Formula 
Temperature corrected factor=Density at 15deg* { 1-{(T-15)*0.00065}}
                                                             
where T is the temperature of the oil
Density@15 is tonne/m3
0.00065 is the Correction factor
                                                                                             
Finally, Step 3
Fuel consumption =Volume*Temperature corrected factor(TCF)
                                                               
Where volume is in m3
TCF is in tonne/m3
Fuel consumption is measured tonnes specified over a period of time generally 24hrs


Fresh water management on board

Practical management of freshwater based on experience would be discussed here. Short voyages, frequent port calls, inefficient water production at times lead to any seafarer nightmare that is WATER RATIONING.

It is also a safety issue as ships designed for the Hyper-mist system require a minimum amount of water in the FW water tanks to ensure localized fixed fire fighting and UMS operation.

At noon total water production and total freshwater ROB are found and reported to the company along with the noon report.

The formula for FW consumption

Water Consumption= F.W ROB(Yesterdays)+FW PRODUCION(last 24 hr)—F.W ROB(Today) 

Depending on vessel and design (TOTAL F.W ROB can include a distilled water tank and drinking water tank)

Water consumption can be calculated from the above formula and depending on the vessel, number crew, general trends can be found out

Reason for abnormally high water consumption
  1. FW being used for deck washing, tank cleaning and other operations
  2. Reduced production from FWG due to poor maintenance(fouled condenser etc) 
  3. leaks in the galley and in different part if accommodations 
  4. leaks in the engine room from the jacket water system and other FW systems
  5. leaks/abnormality  in boiler leading to higher distilled water consumption 
  6. Crew consuming more water as the vessel is operating in hotter regions
Solution
  1. Goes without saying periodic maintenance of FWG to be carried out with PMS of the vessel.
  2. Dosing approved chemical for FWG 
  3. Arresting or repairing all leak in the FW system - engine room, galley, deck, and accommodation.
  4. Carrying out the boiler water test, and maintaining  it within limits 
  5. Carrying out jacket water tests and maintaining within the limit
Proactive steps 
  • Bring it out on safety meeting and training the crew on FW water management
  • Encourage reporting of leaks however small.
  • Pasting attractive poster on water conservation on the common areas (the only cost is printing a page and double-sided tape)
  • Reducing the flush flow rate in all bathrooms using FW flushing systems