Showing posts with label Safety. Show all posts
Showing posts with label Safety. Show all posts

Chain Coupling



What is a Chain Coupler

A chain coupler is a mechanical device used to connect two rotating shafts in various industrial applications. 

Chain couplers are engineered to transmit torque or tension, absorb misalignment, and provide a secure connection between elements. They are widely used in marine engineering, mechanical power transmission, and railway systems.

Constructed of two-strand chains and two sprockets. Can be connected and separated without moving the equipment by winding the chains over and removing them from the sprockets.


  • Excellent Durability :
The coupling provides outstanding durability with the torque distributed to the strong roller chains and surface-hardened sprocket teeth.
  • Absorption of Large Misalignment :
The clearance between the components absorbs a large misalignment of both shafts.

Limitations:

  • Not suitable for high-speed or high-precision systems.
  • Requires regular lubrication and inspection.
chain coupler with grease

Theory of Fire and Backdraft fire



Fire Triangle

Fuel, heat, and oxygen are the three components of fire.

All three components are require to start a fire and absence of any one component will stop the spread of fire


Tetrahedron fire Triangle

The base of a fire tetrahedron represents the fourth component in a fire triangle. It is the ‘chain reaction’ due to the molecular combination of fuel, oxygen and heat energy. 

When you break the chain reaction, fire does not spread.





The four phases of fire

  1. Ignition
  2. Developing
  3. Absolute Fire
  4. Burning Out

  • Ignition phase

When there is sufficient air-vapour mixture and the temperature of the substance exceeds its ignition point, the fire starts.

This fire can be due to an external heat source, auto ignition or spontaneous ignition. Spontaneous ignition is the one in which certain materials become warm during oxidation producing more heat and in turn accelerate the oxidation process.

In the ignition or ‘incipient’ phase, there is a heat flow back to the material due to radiation, which results in a chain reaction and the components will have the ability to sustain fire.

  • Developing phase

During developing phase, the flame spreads on the surface of the material. After sufficient heating, it gives off vapours, which act as a source of heat. Solids and liquids convert to vapour state before combustion. In case of flammable gases, there is a high risk of explosion, because the combustion process takes place at an extremely fast rate.

The burning speed depends on the rate at which the heat source gives off the vapours and its combustibility. Petrol has a very high surface burning speed, while wood has a low surface burning speed.

  • Absolute Fire phase

In this phase, the heat spread on the surface of the material penetrates into the depth of the solid or liquid. Intense flammable vapour will be generated at this stage.

  • Burning Out phase

The fire continues to burn, until it consumes most of the vapour. In the burning out phase,most of the fuel gradually burns out and the fire ‘dies’ thereafter.


Backdraft Fire on Ships

A backdraft is a dangerous explosive event that can occur during a fire when a compartment or enclosed space has a fire smouldering in a low-oxygen environment, and oxygen is suddenly introduced, often when a door or hatch is opened.

How a Backdraft Happens

  • Fire starts in a closed compartment (e.g., engine room, store, cabin).
  • The fire consumes most of the available oxygen, slowing down but continuing to produce heat and flammable gases like CO and unburned hydrocarbons.
  • The space becomes filled with superheated, oxygen-depleted air and dense smoke.
  • When the compartment is suddenly ventilated, such as by opening a hatch or door, fresh air rushes in.
  • The reintroduction of oxygen causes the flammable gases to ignite explosively, often violently.

Sparks from main engine exhaust

Engineer on duty sometimes get dreaded calls from the bridge reporting sparks from the funnel which could lead to panic.



Reasons for sparks from funnel

  1. Slow streaming and frequent maneuvering could have built unburnt soot in the Exhaust Gas economizer.
  2. Lack of maintenance in Exhaust Gas Boiler-Infrequent/delayed water washing.
  3. Fault fuel injector, improper combustion, or incorrect governor setting
  4. Indication for the start of an economizer Fire or a scavenge fire.
  5. Water in the service/ settling fuel  tank or maintaining the wrong viscosity as per FO lab analysis
  6. Improper FO treatment onboard or wrong FO purifier setting
  7. Dirty turbocharger air inlet/ fouled air cooler 
  8. Improper cylinder oil lubrication feed rate.
  9. Dirty scavenge space or choke drains

Prevention

  1. Frequent soot blow and water washing of EGB exhaust gas boiler.
  2. Check the integrity of funnel wire mesh with frequent inspection.
  3. Maintain soot-blowing equipment in good working condition.
  4. Carry out proper maintenance on the main engine as per PMS.
  5. Fuel oil purification, storage, and transfer should be carried out as per the FO lab analysis report recommendation.

Pro Tips

  • Start boiler circulation pump after EGB water washing. Collect/remove soot at the bottom of EGB , this may have to be done multiple times if time permits before departure. 
  • At times sparks do come from the engine exhaust right after EGB water washing so avoid water washing at port.
  • In oil tanker do not carry out soot blow during cargo operation, venting, and tank cleaning operations. Always inform the bridge prior to soot blowing.
  • Remove any combustible material around the poop deck or around the vicinity of the funnel and follow good housekeeping practices. 
  • If sparking occurs keep a crew on standby around the poop deck for fire watch and keep fire fighting equipment on satanby until the problem is resolved.
As always prevention is better than cure so carry out proper maintenance as per PMS, have good watch-keeping and housekeeping practices. Share and guide the crew with personal experiences, and good practices.

Steam hammering Vs Water Hammering

What is Steam hammering?

It happens when there is direct contact of steam with liquid, as hot steam comes in contact with cooler condensate or liquid, creating a low-pressure zone. The liquid then rushes in to fill the low-pressure zone creating a pressure spike. As the steam flow increases, steam carries the water with it a lot of momentum is created and hammers the line loops with tremendous forces causing a lot of stress.


Effects of steam hammering

  • Cause valve failure.
  • Break pipe welds and rupture piping.
  • Failure in heat exchange or tubes.
  • Crack steam trap and pressure gauges.

How to prevent Steam hammering- Pro tips

  • Have a checklist for the start and shutdown of various steam systems onboard.
  • Correct usage of the warm-up valve.
  • Drain the steam line and make it free of condensate
  • Check and repair insulation to reduce  heat wastage and accumulation of condensate
  • Gradual opening and closing of the valve.
  • Ensure steam traps are working satisfactorily.



What is water hammering?

Water hammering is the sudden pressure surge caused by rapid change in the velocity in the pipeline, which sounds like being pounded with a hammer

It is caused when a fluid in motion is forced to change direction or stop abruptly. When a pump is suddenly stopped, or when an open valve is closed suddenly.

How to prevent Water hammering- Pro tips

  • Reduce operating pressure.
  • Open and close the valve slowly.
  • Installing a pressure reducer.
  • Good pipeline control (start-up and shut-down procedure).



MAN OVERBOARD-Action needed to be taken by duty engineer

Man overboard is an emergency situation wherein a crew member falls out to sea no matter where the ship is sailing. In this, we are strictly discussing the action that needs to be taken by the duty engineer. In an actual scenario, the duty engineer (technical team) will be left alone in the engine room as all another crew member would be busy in rescue and recovery.
  • Without thinking, the first action should be to start the standby generator (ASAP) and take it on load -To handle the maneuvering load
  • If in a UMS VESSEL - use REMOTE AUTO START of DG from ECR and take it ON-LOAD (ASAP) in an emergency situation normal warm-up procedure of DG can be waved-off.
  •  Put the all standby main air compressor, deck compressors  in auto  
  • Press up the main air bottle and service air bottles.  
  •  Prepare the main engine for maneuvering 
  •  Stop the freshwater generator (if running)
  •  Adjust and monitor main engine jacket water temperature
  •  Needless to say, all main engine parameter and maneuvering procedure need to be followed depending on the type of vessel
  •  Make sure all DECK AIR VALVE and DECK  FW VALVES are OPEN
  •  Make sure sufficient hydraulic motor are running for DECK HYDRAULIC machinery
  •  Take a quick round in the steering gear room to make sure everything is alright
  • Maintain good communication with the bridge, attend all calls, and request promptly.

The best way to update yourself on the rescue is by keeping a free walkie-talkie on the deck channel.


People react differently in the real situation some people paralyze and other lead and if you feel that you cannot handle the situation just ask for an extra hand.

Disclaimer: Please follow company procedure and duties listed on the muster list these are just additional points from the perspective of an engineer gathered from practical experience.


Bulbous bow

  • A bulbous bow is a protruding bulb at the bow of a ship located just below the normal waterline. As the ship moves through the water, the bulbous bow modifies the flow of water around the hull, thereby reducing drag and increasing speed, range, and stability.
  • Large ships with bulbous bows generally experience a 12% or greater fuel efficiency compared to similar vessels without bulbous bows. Fuel efficiency tends to increase with speed.
  • As a ship with a conventionally-shaped bow moves through the water, a bow waveforms immediately in front of the bow, and a stern wave is generated at the stern of the vessel.
  • The ship consumes energy in the creation of these waves. If the ship has a bulbous bow and is moving at speed, the trough formed by the bulb coincides with and partially cancels out the usual bow wave. Cancellation of the wave stream changes the pressure distribution along the hull and reduces wave resistance.
  • Evidence indicates that a bulbous bow can also improve the trim and stability of the ship at the speed

Leak test done on FRAMO PUMPS

Leak test is carried out on framo pump to check if there is any oil leak from hydraulic side to the cargo side or vice versa via the mechanical seal,basically done to check the integrity of mechanical seal

leak test should be done right after completion of cargo loading, so the air pressure is maintained within the range of 1kg/cm2 to 2.5  kg/cm2

Procedure

1) Open valve D , B in the leak cheakc line( valve C is fully closed)
2) Immediately open valve for introducing air at the pressure of 2.5 kg/cm2
3) Should there be any sign of leakage, collect the leaked liquid in the tray
4) Close valve D and B
close valve A after few minutes
Framo pump diagram
Framo pump diagram

Propeller shaft grounding system

The electrical potential between shaft and hull can also cause a heavy current to flow
 in bearings when the oil film breaks down or is contaminated with seawater. This
current can cause deep pitting of the bearing surface. Excessive wear on the shaft
 bearings can often be traced to this cause.Trouble can be avoided and cathodic
protection extended to the propeller if the shaft is properly earthed with a shaft
 earthing system.

Propeller Shaft Grounding System consists of the following
  • Slip Ring - Elevated silver band reduces dirt for the best possible contact.
  • Brush Holders - Double and single brush holders for grounding and measurement. 
Strong springs for proper brush pressure
  • Silver slip band - Reliable contact. Easy installation
  • Silver brushes - High purity silver brushes for proper shaft grounding
  • Monitoring Meter- Continuously monitoring the shaft potential. (Remote Indicator)


Advantage


  • Serves for a short circuit between the rotating propeller shaft and the ship's hull
  • Can prevent the micro pitting marks at the propeller, on the sliding surfaces of crankshaft                         journalsand main bearings of the engines to be assumed as spark erosion
  • Ensures an excellent potential decomposition and the contact brushes ensure lubrication                                    and long life
  • A remote indicator system in order to achieve a continuous control the effectiveness of the                    wholesystem
  • A continuous slip ring cleaning device to prevent an increase of the residual potential                                  during operation

SQUAT EFFECT

  • The squat effect is the hydrodynamic phenomenon by which a vessel moving quickly through shallow water creates an area of lowered pressure that causes the ship to be closer to the seabed than would otherwise be expected.
  •  This phenomenon is caused when water that should normally flow under the hull encounters resistance due to the close proximity of the hull to the seabed.Leonardo's law causes the water to move faster in water level (where the section is smaller); according to Bernoullì's theorem, a velocity increasing determinates a low-pressure area so that ship is pulled down. This squat effect results from a combination of vertical sinkage and a change of trim that may cause the vessel to dip towards the stern or towards the bow.
  • The squat effect is approximately proportional to the square of the speed of the ship. Thus, by reducing speed by half, the squat effect is reduced by a factor of four.
  • The squat effect is usually felt more when the depth/draft ratio is less than four or when sailing close to a bank. It can lead to unexpected groundings and handling difficulties.

HOW TO CONVERT LEL TO PPM

If we use methane (CH4) as an example, the LEL (lower explosive level) of methane is generally considered to be 5% by volume (5% By Vol). That means the mixture is too lean to burn if there is less than 5% methane present. But at 5%, we can burn or explode if there is an ignition source.

So we call 5% by vol methane the same as 100% LEL.
"5% methane is 100% of the explosive concentration."
  • 100% LEL = 5% methane = 50,000 ppm methane
  • 10% LEL = 0.5% methane = 5000 ppm methane
  • 1% LEL = 0.05% methane = 500 ppm methane


Thumb rule for dummies


  • Multiply the LEL percentage number by 10,000 to get PPM.
  • To convert from PPM to an LEL percentage, divide the PPM by 10,000.





Hyper-mist fire fighting system on ships

Machinary space of 500m3 volume and above should have additional fixed fire fighting system like hyper mist system especially on UMS class vessel

Effects of hyper mist

High-pressure water is injected through a special nozzle which beak it into fine water droplets around 50-200 micron depending on the design.
Effects of these micro-droplets are

  • Remove the latent heat hence giving a good cooling effect
  • Replaces the surrounding air around the fire with droplets that is converted to steam hence effectively replacing the oxygen
  • The floating smoke particle gets absorbed and settled by the fine mist


Normally fitted above

  • main enine
  • auxially engine
  • boiler
  • purifier
  • incinerator area

Operating procedure

  • Normally the system is kept in auto mode activation is by the local sensor, a minimum of two different sensors need to get activated to start the system in auto.
  • Manual start from the control panel and localized start points when needed

Stop procedure

After confirmation of the extinguishing of fire manual stop button in the control panel and local activation points, some system does not have auto-stop

Safety 

  • High/low freshwater tank alarm
  • Electrically operated non return valves
  • Power suply from both MSB and ESB
  • Drain and test valve on the system lines
  • Manual stop button on the control pannel and localized start points
  • It requires a flame and smoke detector to go off to activate the system automatically

How to test the integrity of the sampling line in pump room onboard (oil tanker)


If the integrity of the sample pipe is lost we end end up getting wrong reading for the multi gas detector placed in pump room. Resulting in serious risk to personnel as pump room as it  considered to be an enclosed space.
There are generally two methods

  •  Is to run the multi gas detector by blocking all the sampling tube ends. This will result in a no flow alarm that proves the integrity of sampling line
  • Some of the detector can detect the percentage of nitrogen. Hence the integrity of the line can be tested by using a sample of 99.9% nitrogen.

Reason for having a spring loaded valve and not a normal valve to drain the water from steering room

Ships normally have a spring-loaded valve and not a normal valve to drain the contents from the steering gear room onto the aft bilges.

The main reason is to prevent the leakage of CO2 into the steering gear room when the engine room is flooded with CO2. Most ship have there emergency fire pump located at the steering gear room.

  • Hence to prevent leakage of CO2/toxic fumes leaking into the steering gear room
  • To protect the personnel that is going to operate the emergency fire pump from CO2 poisoning
It is also very important to note that this valve should not be clamped open by any mechanical means as it will not serve the purpose, and CO2 flooding of engine room might be counterproductive , and will be risking the personnel positioned at the steering gear room

Time Delay Unit in CO2 Flooding System

CO2 from the pilot bottles in the release cabinet reaches the main CO2 bottle head assembly through a time delay unit. The function of this time delay unit is to delay the supply of CO2 to the head assembly for 60 – 90 seconds.
 In other words, when valve 2 in the release cabinet is opened, CO2 reaches only after 60 to 90 seconds to the head assembly. Reasons for providing such as delay in the CO2 flooding system are given below.
  • As soon as the CO2 release cabinet opens, the alarm is sounded in the protected space. A time delay gives sufficient time for any personnel in the protected space to escape, even after the operation of both valves in the release cabinet. 
  • If CO2 is released from the main bottles to the common manifold before opening the master valve, there may be difficulty in opening the master valve because of the bulk CO2 pressure acting on it. Because of the time delay, the positive opening of the master valve is ensured before releasing CO2. 
  • Regulation per International Code for Fire Safety System (FSS Code) 2.1.3.2 says, “The pre-discharge alarm can be automatically activated (e. g. by opening the release cabinet door). The alarm shall operate for the length of time needed to evacuate the space, but in no case, less than 20 seconds before the medium is released.”

Followers